Explore our database of over 20,000 parts & never miss a critical date again. 100% free GCP-GCX braindumps demo before buy. Dell End of Life (EOL) means that Dell will no longer sell the hardware for that system, market, or update equipment after a certain date. *Inclusion in the EOSL library does not guarantee Park Place can support that specific device. Our company have 2 deployments (1 single and 1 double X-brick) and uses this technology since 2015. To start that process, first check what version of firmware is on your BBUs via the XtremIO XMS command line interface. Once you start with a given Brick model, you can scale-out only with that Brick model. VMAX 250F/950F models employ 7.68TB and 15.36TB SSDs, Intel Broadwell CPUs, and 12Gb/s SAS-3 back-end shelves, whereas the VMAX 450F/850F models, which GAd just over a year ago, remain stuck on lower capacity SSDs, older CPUs, and 6Gb/s SAS-2 back-end shelves. XtremIO fills a gap in high-end performance where the VMAX level of resiliency or features isnt required. Quote me XtremIO X2. VDI has been mentioned a number of times now as a focus for XtremIO, but what about high-end workloads? https://support.emc.com/products. We take care of all of the technical details to accelerate While XtremIO was quick to hit $1 billion in sales and has added several new features like iCDM, there hasn't been a hardware leap in several years.XtremIO X2 now brings to bear an all-new custom chassis and core software update, XIOS 6.0. Contact Park Place Technologies today to learn about our post-warranty maintenance options. Company Size: <50M USD. IOPS performance scales linearly with each additional X-Brick. With the upgrade from XIOS 2.4 to 3.0, customers had to reload their systems as the upgrade process was destructive. Stay up-to-date on end of life & end of service life with our simple, easy to use database. Scaling with Brick-based scale-out is complex and costly. Power it back on. VMAX: Inefficient, complex, and expensive. X1 had some real shortcomings, such as the inability to extend a configuration in place. They may know more about your computer than someone who works in-house. This claims to have reduced latency by a factor of 5x. You can find the passwords to both on my page here. Excellent solution. The point-in-time compression ratio can and (likely) will be mismatched over time with the level of efficiency possible as your application workloads change over time. New eras are often when revolutions occur. Even 8K duplicates are missed unless the database / VM / file system has been tuned to align at the 8K boundary. infrastructure. Different Brick models are NOT mixable / upgradable to other Brick models. Software migration packages are simply not equivalent. With Pure, they can get all three with the new (Orange) //X. This goes back to the VDI discussion XtremIO is price sensitive to the level of data de-duplication that can be achieved. Direct: 952-525-0700 Gain in-depth understanding of how to leverage and optimize XtremIO features and capabilities in specic application areas. In comparison, FlashArray delivers average 11:1 total reduction (dedupe + compression + thin provisioning) and 5:1 data reduction (dedupe + compression) or 2x+ more than VMAX All-Flash or XtremIO. The best part about this is that the batteries had simply reached a pre-determined time limit on when Eaton believes they should no longer be relied on, they hadnt failed a self test. If you dont have a lot of extra money to spend on upgrades, you can still use your existing hardware with the help of TPM. So although theres overlap, there are unique features only VMAX offers. As ever, this is the challenge, how to remain competitive in a market that is stagnant or even shrinking. delltechnologies.com//storage/xtremio-all-flash, "Compare XtremIO vs. No new VMAX features. The battery backup unit, previously used to de-stage data from memory in the case of power loss, has been replaced. You really cant make this fucking shit up. RAID 5 vs. But wait, theres more; as shipped between at least 2015-2016, this iteration of XtremIO with Eaton 5p 1550 UPSs is a ticking time bomb, because the UPS has a battery lifetime counter that counts down until zero is reached, and upon reaching zero, goes into a degraded state. Unlike the 450F/850F models, VMAX 250F and the new VMAX 950F support Big SSDs (i.e. It brings Tier 1 performance, reliability, and effortless efficiency without compromise. PROCESSING PRACTICE: CPU & SYSTEM ARCHITECTURE, EMC close to buying XtremIO for $400-$450m, Traditional array all-flash retrofits knock XtremIO off top sales rung, Dell EMC Introduces New All-Flash Storage Systems to help Customers Modernize Their Data Centres and Transform IT, Garbage Collection #008 Chris Travels Commvault, NetApp and SFD14, Dell EMC Presents High-End Systems at Storage Field Day 14. If it is not charged to at least 70%, the XIO will still refuse to boot, so that's fun. X-Bricks can be combined in clusters for additional scaling of both capacity and performance. Dell discontinuing support for your equipment doesnt imply it needs to be replaced. Many thanks EMC XTREMIO X2-S 400GB 72-SLOT CHASSIS Category. In comparison, the Pure FlashArray//X uses Intel Broadwell CPUs and we have a proven history of introducing newer Intel CPU-based controllers every 12 to 18 months. Dell SC Series is ranked 14th in All-Flash Storage with 10 reviews while Dell XtremIO is ranked 21st in All-Flash Storage with 6 reviews. Allowing you to extend the support cycle and maximize the value of your hardware by saving 30 - 40% against that XtremIO contract. your business effectively. 11-29-2021 10:27 AM. XtremIO is an all-flash storage array, designed from the ground up to unlock flash's full performance and deliver array-based capabilities leveraging unique characteristics of SSDs, based flash media. We can provide hardware maintenance for your Dell EMC EOSL equipment at 30-40% less than your OEM contracts. End of service: 31/08/2023. OEMs specialize in their equipment, but TPM programs focus on the needs of your company. Need to know EMC XTREMIO X2-S INFINIBAND SWITCH EOL & EOSL Date? From a hardware perspective, there are now two configurations, the X2-S and X2-R. If youre tired of keeping track of Dell End of Service (EOSL) dates, dont sweat it anymore. The XIOS operating system software, which sits on top of a Linux kernel inside each storage controller, manages the system's functional modules, RDMA over InfiniBand operations, monitoring and memory pools. With a TPM company, you can push back the cost of new equipment. solution. Explore our database of over 20,000 parts & never miss a critical date again. Unity all-flash storage system for VDI", "Dell EMC all-flash moves focus on VMAX, XtremIO and Isilon", "Battery Ventures Leads $14 Million in Series B Investment Round for Israel-Based XtremIO", "XtremIO Achieves $1 Billion In Bookings In Just 588 Days", "Why Israel is a hotbed for flash storage innovation", "EMC's XtremIO array: Everything we know about new all-flash box", "XtremIO Introduces iCDM To Tackle The Issue Of Copy Data", "Deep Dive XtremIO X2 Dell EMC World 2017", "XtremIO Hardware/Software Overview & Architecture Deepdive", https://en.wikipedia.org/w/index.php?title=Dell_EMC_XtremIO&oldid=1089514576, Creative Commons Attribution-ShareAlike License 3.0, This page was last edited on 24 May 2022, at 07:36. XtremIO X2 Specifications. The silver lining is that every forklift is an opportunity for customers to evaluate industry-leading alternatives, such as FlashArray//X. Dell EMC is promoting X2-S systems for higher de-duplicating workloads, such as VDI. X2-T comes in a single X-Brick configuration that scales from 34.5TB raw up to 69.1TB raw or 369TB effective capacity given a 6:1 storage efficiency. Reconnect it exactly as it was connected before, i.e. Leaving you to focus on running Still NOT Evergreen: Future proofing and forklift upgrades remain a costly challenge on both XtremIO and VMAX. Dell EMC XtremIO. XIOS features global inline deduplication and compression, thin provisioning, snapshot architecture, XDP Data Protection and full VAAI Integration.[13]. An upgrade will still be necessary at some point, but TPM can help delay it. For example, if you start with X2-S, you scale with X2-S. Getting to X2-R is a forklift upgrade from X2-S. As a result, XtremIO was heavily marketed. Responsible on Product platform layer. Park Place Technologies makes it easy to find the latest End of Life (EOL) and End of Service Life (EOSL) information for your XtremIO hardware. And those differences create a sharp contrast for customers. While the VMAX All-Flash models support NVMe-enabled vault drives, these are not in the normal IO path, where NVMe is needed to unlock its real benefits. Before we evaluate the products in detail, lets first consider the product dimensions that are critical to truly modernize, support new and existing apps, and drive both business and IT transformation in the cloud era: Providing a framework for the subsequent evaluation, Figure-1 below depicts a comparison, from Pures perspective, of the all-flash storage arrays discussed herein: 1. From a hardware perspective, there are now two configurations, the X2-S and X2-R. It also targets organizations with large VDI deployments. Over-promise and under-deliver: creative data efficiency claims, Dell EMC 4:1 Data Efficiency Guarantee requires thin provisioning and snapshots. OurTrueView Risk Assessment offers an unbiased risk evaluation for each type of device in your IT environment. Fixed metadata misses any duplicates that are not an exact 8K match. 4. The architecture is based on closely coupled scale-out nodes called X-Bricks, connected by a 40Gb/s InfiniBand switch when 2 or more nodes are in a configuration. We understand that implementing new technology can be challenging and In our view this is a rational position VMAX where reliability trumps efficiency, and XtremIO where efficiency (via purpose-built data reduction) trumps reliability. The previous X1 systems had three X-Brick capacities (10, 20 and 40TB) based on three drive sizes (400Gb, 800GB, 1.6TB). Learn how Top Gun provides the right support to help you keep, fine-tune and maintain your End of Life EMC systems. Im not sure if the counter is visible; did you try the Battery lifecycle reset menu choice? Individual X-Bricks can scale up by adding as few as two SSDs at a time to any single brick. On the off chance Eaton ultimately removes the tools, or releases a version that cant be downgraded from, here are my local copies of things: Version 35 (unfortunately never saved 26, which got the job done): https://www.ispcolohost.com/publicshare/eaton_5p_lvhv11_e0_v03_18_0035_tl00.zip. Lets get started! [5][6] Known as the home of the USB flash drive, Israel fostered companies like XtremIO, M-Systems, Anobit and others that were attracting a lot of attention from U.S.-based firms for their talent and technology. The Dell EMC XtremIO team recently presented at Storage Field Day 14. So lots of extra redundancy (like battery backup and dual nodes) was put into each X-Brick configuration. You saved us today man. At a high-level, Dell EMC has refreshed and released two potentially overlapping products, and we applaud them for clarifying what each is for: VMAX for tier 1 workloads and consolidation, and XtremIO for point VDI and snapshot heavy environments like test & development (test/dev). Toll Free: 800-409-3132, 2023 NorthSmart | All Rights reserved | Privacy Policy | Terms of Service. Base your decision on 30 verified in-depth peer reviews and ratings, pros & cons, pricing, support and more. Up to 8 X-Bricks can be combined into a single cluster with a raw capacity of up to 1.1 PB, which the company claims is an effective capacity of 5.5 PB due to the 6:1 data efficiency ratio achieved through what it calls intelligent data packing.[10] X-Brick interconnectivity is achieved using 40Gbps InfiniBand. The X2-T offers all the features and data services of the XtremIO family in a lower-cost configuration designed for the midrange. Dell EMC XtremIO X2, XtremIO, XtremIO X2. Advisories. Dell EMC XtremIO X2 maintenance and support are required to ensure that the system continues to deliver optimum peak performance without any errors. CryptoSaurus, Internet Security and Acceleration Server, Windows Subsystem for UNIX-based Applications. I am not sure its right or not. EMC VMAX 450F and 850F go EOSL October 31, 2023. You can save money on post-EoL OEM services by working with a TPM company. By extending the life of your The X2-S model uses smaller drives (400GB), so scales from 7.2TB to a maximum of 28.8TB per X-Brick. Atlanta, Georgia 30339 With Pure, you get all three. However, the reason I say to look for this is because your array will refuse to power on if the Eaton firmware is not the version EMC wants it to be at. 10 Dell CloudIQ: A Detailed Review . This has significantly reduced cabling but also will deliver power savings. Select a Model. Base your decision on 13 verified in-depth peer reviews and ratings, pros & cons, pricing, support and more. NorthSmart can provide support for X2-SD-SWITCH-FD hardware after the end of official support date, saving you money in the process, As a If your products are at the end of their life or support life, you may feel like you are stuck. Next, you need both the current version (26) and the firmware install tool: https://powerquality.eaton.com/Support/Software-Drivers/Downloads/5P-UPS-firmware.asp?cx=55. Wait for it to charge, and then finally your first storage controller should come back online. A PowerShell script was used to clone 800 VMs using the Generic VM Template, executed in eight iterations of 100 clones at a time ; the clones were powered on and began generating I/O after creation. [12] These distributed (across different controllers) software modules handle each individual I/O operation, which traverses the cluster. In this blog, well compare the newly announced XtremIO X2 and VMAX All-Flash 950F model to the new (and more orange) X in town, our FlashArray//X.
xtremio x2 end of life
Posted by